Citronic

TRIX-8 Multi use Temperature Data Recorder

Description: TRIX-8 Multi use Temperature Data Recorder TRIX-8 The LogTag® TRIX-8 data logger is a versatile, wide range, multi-trip Temperature Recorder, featuring high resolution temperature readings over a measurement range of -40°C to +85°C (-40°F to +185°F). The LogTag® TRIX-8 calibrated temperature data logger is equipped with a unique external temperature sensor arrangement providing fast reaction time to temperature change. Protect the TRIX-8 from damage with a LogTag Protective Enclosure for your data logger. Of course, we offer our temperature data logger calibration service for this and all of our data loggers. PLEASE ALLOW UP TO 2 BUSINESS DAYS FOR CERTIFICATION COMPLETION, IF ORDERED. IMPORTANT: Each location (not each logger) requires a LogTag Cradle in order to program and retrieve data from the logger. Interface Cradle Using the LogTag® Interface Cradle and the freely available companion software LogTag® Analyzer, the LogTag® TRIX-8 data logger is easily set-up for recording including delayed start, sampling interval, number of readings and configuration of conditions to activate the 'ALERT' indicator. LogTag® Analyzer also provides facilities for charting, zooming, listing data statistics and allows exporting the data to other applications such as MS Excel once the data has been downloaded. A real time clock provides date/time stamps for each temperature reading. Push-to-start button with optional delay or a specific time & date. This portable temperature data logger comes with comprehensive customization options including alert settings, sample interval and trip duration. Complies with industry standards including EN12830. WHO PQS Prequalified under E006 devices : PQS Code E006/006 Highlights Alert indicator – indicates if readings are outside of preset limits OK indicator indicates if still recording and if readings within configured limits Inspection mark in log by push button Push Button Logging start Rapid Download! Takes only seconds to download recordings 'Pre-Start' logging - LogTag® can be configured to record even if it has not been started. High performance at low cost Credit card sized case – thin enough to be easily mailed “letter rate”. Real time clock records time & temperature simultaneously Easy to use LogTag®Analyzer software that runs on any PC configures LogTag® for recording then downloads resulting data for analysis. Data can also be exported to formats compatible with other applications such as Excel Highly reliable and accurate Re-calibration is possible to achieve higher accuracy possible Specifications Model Trix-8 Measurement Range -40°C ~ +85°C (-40°F ~ +185°F) Resolution < 0.1°C for -40°C ~ +40°C, < 0.2°C for +40°C ~+80°C Accuracy Better than ±0.5°C for -20°C~ +40°C. Better than ±0.7°C for -20°C~ -30°C & +40°C~+60°C Better than ±0.8°C for -30°C~ -40°C & +60°C~+80°C Sensor Reaction Time Typically less than 5 minutes(T90) in moving air (1m/s). Capacity 8032 readings (16K bytes memory) Sampling Frequency Adjustable, 30 sec to several hours Logging Start Options Push button start or specific date & time. Optional start delay of up to 18hours. Recording Indication Flashing 'OK' indicator / flashing 'ALERT' indicator. Download Time Typically with full memory (8000 readings) in less than 5 secs depending on computer or readout device used. Environmental IP65 (roughly equivalent to NEMA 4) Power Source 3V LiMg battery Battery Life 2 ~ 3 years of normal use (based on 15 minute logging, download data monthly. Size 86mm(H)x54.5mm(W)x8.6mm(T) Weight 35g Case Material Polycarbonate Other Features • Logging start by push button or specific date/time start • Optional clearing of alert indication by push button (places inspection make at same time). • Download inspection mark recorded in LogTag memory every time LogTag is downloaded. • 'Prestart' fail-safe logging (records temperature data even if not started) • Low Battery indication in software. • Comprehensive Alert indicator configuration. • Calibration to achieve higher accuracy possible. Calibration In order to calibrate your LogTag Recorder, we use the LogTag Calibrate software. LogTag Recorders releases our LogTag Calibrate software only to selected users who have suitable equipment and credentials relating to standard practices of Temperature and/or Humidity calibration.If you require calibration of your logger, please contact Tech Instrumentation at 303-841-7567 ext 2. Calibrate after a battery change Loggers that have had their case opened have potentially been exposed to electrostatic effects. In addition, units that had their battery replaced may not have been correctly hibernated or may have suffered from memory corruption if battery voltage was critically low during use. They should therefore be validated for correct operation and performance after the battery change. The preferred way of doing this is by way of re-calibration, where ideally the product should be exposed to its full temperature measuring range. Additional Info Response Time for TRIX-8 The most common industry standard expression for temperature reading stabilization time is the ‘T90’. This is defined as the typical time taken of a given sensor in a given environment (e.g. moving air, still air, liquid etc.) to register 90% of an immediate step change in temperature. The T90 of TRIX-8 is typically less than 5 minutes in moving air of 1m/s. As the thermal step response is basically dependent on the latent heat of the two thermal masses involved (the Logger and the surrounding environment) and the rate of thermal transfer between them, the T90 is the same irrespective of the difference of temperatures though at extremes (water freezing and boiling points for example) the environment does not behave homogeneously thereby changing the rates of thermal conduction and therefore changing the resulting T90 value. For example: in a situation of a 25°C step change say starting at 10°C and moving to 35°C in moving air of 1m/s, the TRIX-8 will typically register 90% of the step after less than 5 minutes – i.e. 0.9×25 = 22.5 -> 10+22.5 = registering 32.5°C within 5mins. The T90 for a 15°C step in 1 m/s moving air (say 10°C to 25°C) will be the same. 0.9×15 = 13.5°C +10 = registering 23.5°C within 5mins. T90 is different in slower moving air or still air, though air is never totally ‘still’ when a temperature difference exists as convection will take place. TRIX-8 Multi use Temperature Data Recorder TRIX-8 The LogTag® TRIX-8 data logger is a versatile, wide range, multi-trip Temperature Recorder, featuring high resolution temperature readings over a measurement range of -40°C to +85°C (-40°F to +185°F). The LogTag® TRIX-8 calibrated temperature data logger is equipped with a unique external temperature sensor arrangement providing fast reaction time to temperature change. Protect the TRIX-8 from damage with a LogTag Protective Enclosure for your data logger.  Of course, we offer our temperature data logger calibration service for this and all of our data loggers. PLEASE ALLOW UP TO 2 BUSINESS DAYS FOR CERTIFICATION COMPLETION, IF ORDERED. IMPORTANT:  Each location (not each logger) requires a LogTag Cradle in order to program and retrieve data from the logger.   Interface Cradle Using the LogTag® Interface Cradle and the freely available companion software LogTag® Analyzer, the LogTag® TRIX-8 data logger is easily set-up for recording including delayed start, sampling interval, number of readings and configuration of conditions to activate the 'ALERT' indicator. LogTag® Analyzer also provides facilities for charting, zooming, listing data statistics and allows exporting the data to other applications such as MS Excel once the data has been downloaded. A real time clock provides date/time stamps for each temperature reading. Push-to-start button with optional delay or a specific time & date. This portable temperature data logger comes with comprehensive customization options including alert settings, sample interval and trip duration. Complies with industry standards including EN12830. WHO PQS Prequalified under E006 devices : PQS Code E006/006 Highlights Alert indicator – indicates if readings are outside of preset limits OK indicator indicates if still recording and if readings within configured limits Inspection mark in log by push button Push Button Logging start Rapid Download! Takes only seconds to download recordings 'Pre-Start' logging - LogTag® can be configured to record even if it has not been started. High performance at low cost Credit card sized case – thin enough to be easily mailed “letter rate”. Real time clock records time & temperature simultaneously Easy to use LogTag®Analyzer software that runs on any PC configures LogTag® for recording then downloads resulting data for analysis. Data can also be exported to formats compatible with other applications such as Excel Highly reliable and accurate Re-calibration is possible to achieve higher accuracy possible     Specifications Model Trix-8 Measurement Range -40°C ~ +85°C  (-40°F ~ +185°F) Resolution < 0.1°C for -40°C ~ +40°C, < 0.2°C for +40°C ~+80°C Accuracy Better than ±0.5°C for -20°C~ +40°C. Better than ±0.7°C for -20°C~ -30°C & +40°C~+60°C Better than ±0.8°C for -30°C~ -40°C & +60°C~+80°C Sensor Reaction Time Typically less than 5 minutes(T90) in moving air (1m/s). Capacity 8032 readings (16K bytes memory) Sampling Frequency Adjustable, 30 sec to several hours Logging Start Options Push button start or specific date & time. Optional start delay of up to 18hours. Recording Indication Flashing 'OK' indicator / flashing 'ALERT' indicator. Download Time Typically with full memory (8000 readings) in less than 5 secs depending on computer or readout device uséd. Environmental IP65 (roughly equivalent to NEMA 4) Power Source 3V LiMg battery Battery Life 2 ~ 3 years of normal use (based on 15 minute logging, download data monthly. Size 86mm(H)x54.5mm(W)x8.6mm(T) Weight 35g Case Material Polycarbonate Other Features • Logging start by push button or specific date/time start • Optional clearing of alert indication by push button (places inspection make at same time). • Download inspection mark recorded in LogTag memory every time LogTag is downloaded. • 'Prestart' fail-safe logging (records temperature data even if not started) • Low Battery indication in software. • Comprehensive Alert indicator configuration. • Calibration to achieve higher accuracy possible.   Calibration In order to calibrate your LogTag Recorder, we use the LogTag Calibrate software. LogTag Recorders releases our LogTag Calibrate software only to selected users who have suitable equipment and credentials relating to standard practices of Temperature and/or Humidity calibration. If you require calibration of your logger, please contact Tech Instrumentation at 303-841-7567 ext 2. Calibrate after a battery change Loggers that have had their case opened have potentially been exposed to electrostatic effects. In addition, units that had their battery replaced may not have been correctly hibernated or may have suffered from memory corruption if battery voltage was critically low during use. They should therefore be validated for correct operation and performance after the battery change. The preferred way of doing this is by way of re-calibration, where ideally the product should be exposed to its full temperature measuring range.  Additional Info  Response Time for TRIX-8 The most common industry standard expression for temperature reading stabilization time is the ‘T90’. This is defined as the typical time taken of a given sensor in a given environment (e.g. moving air, still air, liquid etc.) to register 90% of an immediate step change in temperature. The T90 of TRIX-8 is typically less than 5 minutes in moving air of 1m/s. As the thermal step response is basically dependent on the latent heat of the two thermal masses involved (the Logger and the surrounding environment) and the rate of thermal transfer between them, the T90 is the same irrespective of the difference of temperatures though at extremes (water freezing and boiling points for example) the environment does not behave homogeneously thereby changing the rates of thermal conduction and therefore changing the resulting T90 value. For example: in a situation of a 25°C step change say starting at 10°C and moving to 35°C in moving air of 1m/s, the TRIX-8 will typically register 90% of the step after less than 5 minutes – i.e. 0.9×25 = 22.5 -> 10+22.5 = registering 32.5°C within 5mins. The T90 for a 15°C step in 1 m/s moving air (say 10°C to 25°C) will be the same. 0.9×15 = 13.5°C +10 = registering 23.5°C within 5mins. T90 is different in slower moving air or still air, though air is never totally ‘still’ when a temperature difference exists as convection will take place.   × × × × Shipping info Click the Shipping & Payments tab above the listing description for more info Click the Shipping & Payments tab above the listing description for more info! Additional delivery notes PICK UP OPTION Sorry, our items are NOT available for pick-up. PAYMENT Immediate payment is required upon selecting "Buy It Now" or upon checking out through the cart. We accept payment via U.S. PayPal accounts and all Major Credit Cards, Debit Cards & Google Pay. We are legally required to collect sales tax in those states and localities where we maintain a physical presence (nexus). The applicable amount of sales tax charged to an order will be calculated based on the shipment destination's state and local sales tax laws. Thank you for shopping with us on eBay! Additional Information No additional information at this time Ask seller a question You might also like 1236-17 Thermometer 1236-70 Espresso Thermometer 1246-01 Pocket Test Thermometer 1246-02 Pocket Test Thermometer Contact To contact our Customer Service Team, simply click the button here and our Customer Service team will be happy to assist. Ask seller a question © Tech Instrumentation Shipping & Payments Click the Shipping & Payments tab above the listing description for more info Payment Accepted Payment Methods Immediate payment is required upon selecting "Buy It Now" or upon checking out through the cart. We accept payment via U.S. PayPal accounts and all Major Credit Cards, Debit Cards & Google Pay. We are legally required to collect sales tax in those states and localities where we maintain a physical presence (nexus). The applicable amount of sales tax charged to an order will be calculated based on the shipment destination's state and local sales tax laws. Thank you for shopping with us on eBay! Returns Returns are accepted Items must be returned within 30 days of the auction ending Buyer will pay for return shipping. eBay integration by

Price: 47 USD

Location: Elizabeth, Colorado

End Time: 2024-09-04T20:52:13.000Z

Shipping Cost: N/A USD

Product Images

TRIX-8 Multi use Temperature Data RecorderTRIX-8 Multi use Temperature Data RecorderTRIX-8 Multi use Temperature Data Recorder

Item Specifics

Return shipping will be paid by: Buyer

All returns accepted: Returns Accepted

Item must be returned within: 30 Days

Refund will be given as: Money back or replacement (buyer's choice)

Return policy details:

Brand: LogTag

Available Variations

Color: 1+

Price: 35.95 USD

Available Quantity: 3

Quantity Sold: 3

Color: Do not add Docking Station

Price: 47 USD

Available Quantity: 101

Quantity Sold: 1

Color: Add Docking Station

Price: 149.82 USD

Available Quantity: 1

Quantity Sold: 1

Recommended

LOT OF 50 LogTag TICT-iS0 Disposable Freeze  Indicator NO ALARMS Never Used
LOT OF 50 LogTag TICT-iS0 Disposable Freeze Indicator NO ALARMS Never Used

$199.99

View Details
LogTag TREL-8 Dry Ice Low Temperature Recorder with External Probe
LogTag TREL-8 Dry Ice Low Temperature Recorder with External Probe

$69.00

View Details
LogTag TRIX-8 Temperature Recorder, multi-use
LogTag TRIX-8 Temperature Recorder, multi-use

$32.00

View Details
LogTag TREX-8 Multi-Use Temperature Logger with External Probe
LogTag TREX-8 Multi-Use Temperature Logger with External Probe

$69.00

View Details
Logtag Glycol Buffer Bottle for Temperature Probes.
Logtag Glycol Buffer Bottle for Temperature Probes.

$25.00

View Details
2003 Alabama VANITY LOG-GUY License Plate Tag Original
2003 Alabama VANITY LOG-GUY License Plate Tag Original

$39.99

View Details
Steinbach Birds On Log Germany Wooden Christmas Ornament Used No Box Tag
Steinbach Birds On Log Germany Wooden Christmas Ornament Used No Box Tag

$38.95

View Details
LogTag LTI-HID Desktop USB Interface Cradle (New!) Docking Station W USB Cable
LogTag LTI-HID Desktop USB Interface Cradle (New!) Docking Station W USB Cable

$49.00

View Details
Fenton Light Blue Bird on Log Figurine With Tag
Fenton Light Blue Bird on Log Figurine With Tag

$22.50

View Details
(2) PIMM Log Tag Temp Recorder TRIX-8 Pre-owned
(2) PIMM Log Tag Temp Recorder TRIX-8 Pre-owned

$10.00

View Details