Description: Power Quality Analyzerr With FR008 Current Clamp Of True RMS Current 10mA-10.0A Power Quality Analyzer also named: Intelligent Three Phase Power Quality Analyzer, Multifunctional Power Quality Analyzer, which simultaneous with the functions of harmonic Analyzer, phase volt-ampere meter, electric parameter tester. It apply to electricity industry, petrochemical, metallurgy, railway, mining enterprises, scientific research institution, metrology department. Especially suitable for comprehensive analysis and diagnosis on all the voltage, current, power, power, harmonic, phase electric parameters. ES4000 Power Quality Analyzer is a comprehensive test instrument carefully developed by our company and specially designed for field test of three phases, multi-functional and intelligent, concise man-machine operation. It is easy to use, large LCD screen display, high resolution, interface in both Chinese and English, shock-proof shell structure and so on. Can simultaneously measure the 4-channel current (ABC three phase and neutral wire current), 4-channel voltage (ABC three-phase voltage and neutral line voltage to ground), the peak value of current voltage, maximum/minimum value over a period, three-phase imbalance factor, short-time voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor and displacement power factor, active power, reactive power, apparent power, total harmonic distortion and harmonic, etc; Display real-time waveform, harmonic ratio bar charts of current voltage; Dynamically capture instantaneous change of voltage current, monitoring starting current, monitoring the power parameters and generate the alarm list, generate the trend chart for a long time record test data.
▲Power supply:Rechargeable lithium-ion battery packs 9.6V, backup charger.
▲Battery indicator:Battery symbol shows dump energy. When the voltage is too low, automatic shutdown after the 1 minute.
▲Power consumption:Current consumption of normal test 490 mA, continuous working for 10 hours.
▲Display mode:LCD color screen, 640dots×480dots, 5.6 inches, display domain: 116mm×88mm.
▲Size of clamp:
FR008 small sharp current clamp: 8mm×15mm;
FR020 circle current clamp: 20mm×20mm;
FR050 circle current clamp: 50mm×50mm.
FR300R Flexible Coil Current Sensor (with Integrator) : Ф300mm
▲Instrument dimensions:L×W×H: 277.2mm × 227.5mm × 153mm.
▲Number of channels:4U/4I.
▲Phase-to phase voltage:1.0V~2000V.
▲Phase-to-neutral voltage:1.0V~1000V.
▲Current
FR008 current clamp: 10mA~10.0A;
FR020 current clamp: 0.10A~100A;
FR050 current clamp: 1.0A~1000A;
FR300R Flexible Coil Current Sensor (with Integrator) : 10A ~ 6000A
▲Frequency:40Hz~70Hz.
▲Parameters of electricity:W, VA, Var, PF, DPF, cosφ, tanφ.
▲Energy parameters:Wh, Varh, Vah.
▲Harmonic:Order 0~50.
▲Total harmonic distortion:Order 0~50, each phase.
▲Expert mode:Yes.
▲Number of Transient records:150 sets.
▲Voltage flicker:Yes.
▲Starting current mode:Yes, 100 seconds.
▲3 phases unbalance:Yes.▲Record:300 days(simultaneous recording 20 parameters, record one point every 5 seconds).
▲Min/Max recorded value:Measurement of maximum and minimum values over a period of time.
▲Alarm:40 different types of parameter selections, 12,800 sets alarm logs.
▲Peak:Yes.
▲Phasor diagram display:Automatically.
▲Capacity of snapshots:60.
▲Menu language:English/Chinese.
▲Communication:USB.
▲Automatic switching off:When an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress, the device is not automatic switching off.In other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute.
▲Backlight function:Yes, suitable for use at night and dark place.
▲Weight
Host: 1.6kg (with battery).
FR008 small sharp current clamp: 168g×4;
FR020 circle current clamp: 252g×4;
FR050 circle current clamp: 463g×4;
FR300R Flexible Coil Current Sensor (with Integrator) : 280g×4;
▲Test wires and power adapter: 800g;
▲Total weight: about 10.8kg (with packaging).
▲Length of voltage test wire:3m.
▲Length of current sensor wire:2m.
▲Working temperature and humidity:-10°C~40°C; below 80%Rh.
▲Storage temperature and humidity:-10°C~60°C; below 70%Rh.
▲Input impedance:Input impedance of test voltage: 1MΩ.
▲Withstand voltage:Withstand 3700V/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell.
▲Insulation:Between instrument wiring and shell ≥10MΩ.
▲Structure:Double insulation, with insulation vibration-proof sheath.
▲Safely rules:IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2.
Price: 2150 USD
Location: hefei
End Time: 2024-02-19T01:37:38.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: HFLH
Phase Configuration: 3-Phase
Unit Type: Unit
MPN: HFLH231012
Current Measurement Range: 10mA~10.0A
Country/Region of Manufacture: China
Unit Quantity: 1
Voltage Measurement Range: 2000V
Current clamp: R008