Description: CONTEC Patient Monitor co2 Capnograph Vital Signs Monitor 6 parameter ETCO2 IBP NEW 1.Introduction The monitor is applicable for clinical monitoring in operating room, postoperative observation room, ICU/CCU ward, emergency room, etc. of adult, pediatric and neonate. The patient's vital parameters (ECG (including ST-segment measurement and arrhythmia analysis), RESP, SpO2, PR, NIBP, TEMP, IBP and CO2, etc.) can be monitored. Monitored information can be displayed, reviewed, printed and stored.. Function 1)13.1" high-definition touch screen design, easy and convenient to operate, elegant and concise in appearance. 2)Independent physiological and technical alarm function, convenient for medical staff to quickly know patient’s condition. 3)Luminous “ON / OFF” button design, convenient to operate at night. 4)Modular design: the modules can be configured and combined flexibly and conveniently, expanded and upgraded at any time, meets the monitoring requirements of different departments on different parameters. 5)Support dynamic hot-plugging parameter module: no need to restart the device, plug-and-play, change the monitoring parameters at any time as clinical requirements. 6)Adopt high-performance processor, stable, reliable and fast to process information. 7)Patient information can be rapidly entered, patient type (adult / neonate / pediatric) can be quickly switched, meets the requirements of different departments. 8)Abundant analysis functions: 23 arrhythmia, full-lead ST-segment and pacing analysis; multiple calculation functions (such as calculation of drug concentration, titration table, hemodynamics, ventilation, oxygenation, renal function, etc.). 9)With the functions of waveform freezing, holographic waveform storage and review. 10)Automatic data storage in case of power failure; optional built-in memory card, achieves large-capacity data storage. 11)With HDMI expansion interface, the display screen can be connected according to clinical requirements. 12)Built-in large-capacity detachable lithium battery, ensures uninterrupted monitoring. 13)Fanless design, ensures no noise and low power consumption during working. 14)3-channel built-in recorder used to print real-time waveform is optional. 15)Connect to Central Monitoring System developed by our company by WiFi / Wired, convenient to transmit patient’s real-time data. 16)Standby mode, be applied to ICU, avoids affecting patient’s rest, one-button switching, reduces the workload of medical staff. Performance (1)ECG Lead type: 3-lead: I, II, III 5-lead: I, II, III, aVR, aVL, aVF, V 12-lead: I, II, III, aVR, aVL, aVF, V1,V2,V3,V4,V5,V6 Gain: 2.5 mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV, 40 mm/mV Scan speed: 12.5 mm/s, 25 mm/s, 50 mm/s HR Measurement and alarm range: Adult: 15 ~ 300 bpm Pediatric/neonate: 15 ~ 350 bpm Resolution: 1 bpm Accuracy: ± 1 % or ± 1 bpm, whichever is greater ST-segment detection Measurement and alarm range: - 2.0 mV ~ + 2.0 mV Accuracy: - 0.8 mV ~ + 0.8 mV: ± 0.04 mV or ± 10 %, whichever is greater Other range: unspecified Arrhythmia analysis: 23 kinds Pacemaker: yes (2)RESP Measurement mode: R-F (RA-LL) impedance Respiration rate: Measurement range: Adult: 0 rpm ~ 120 rpm Pediatric/neonate: 0 rpm ~ 150 rpm Resolution: 1 rpm Accuracy: 7 ~ 150 rpm, ± 2 rpm or ± 2 %, whichever is greater; 0 ~ 6 rpm, unspecified Apnea alarm: 10 ~ 120 s, not alarm Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50mm/s (3)NIBP Measurement mode: Oscillometry Working mode: Manual/AUTO/Continuous Measurement interval in AUTO mode: 1 min, 2 min, 2.5 min, 3 min, 5 min, 10 min, 15 min, 20 min, 30 min, 1 h, 1.5 h, 2 h, 3 h, 4 h, 8 h Measurement period in Continuous mode: 5 minutes Measurement and alarm range: 10 ~ 270 mmHg Resolution: 1 mmHg Cuff pressure accuracy: ± 3 mmHg Measurement accuracy: Maximal mean deviation: ± 5 mmHg Maximal standard deviation: 8 mmHg Over-pressure protection: Adult mode: 297 ± 3 mmHg Pediatric mode: 240 ± 3 mmHg Neonatal mode: 147 ± 3 mmHg (4)CONTEC SpO2 Measurement range: 0 % ~ 100 % Resolution: 1 % Accuracy: 70 % ~ 100 %, ± 2 %; 0 % ~ 69 %, unspecified PR Measurement and alarm range: 25 ~ 250 bpm Accuracy: ± 2 bpm or ± 2 %, whichever is greater (5)Nellcor SpO2 Measurement range: 1 % ~ 100 % Measurement accuracy: 70 % ~ 100 %: ± 2 % (adult / pediatric) 70 % ~ 100 %: ± 3 % (neonate) 0 % ~ 69 %: unspecified Nellcor PR Measurement range: 20 ~ 300 bpm; Measurement accuracy: 20 ~ 250 bpm, ±3 bpm; 251 ~ 300 bpm: unspecified; Upper limit of alarm: upper limit - 2 ~ 300 bpm; Lower limit of alarm: 20 bpm ~ lower limit + 2 bpm (6)Masimo SpO2 Measurement range: 1 % ~ 100 % Measurement accuracy: 70 % ~ 100 %: ± 2 % (adult / pediatric, under conditions of no motion), ± 3 % (under conditions of motion) 70 % ~ 100 %: ± 3 % (neonate, under conditions of no motion) 1 % ~ 69 %: unspecified Masimo PR Measurement range: 25 ~ 240 bpm Measurement accuracy: ± 3 bpm (under conditions of no motion), ± 5 bpm (under conditions of motion) Upper limit of alarm: upper limit - 2 ~ 240 bpm Lower limit of alarm: 25bpm ~ lower limit + 2 bpm (7)TEMP Channel: dual-channel Measurement range: 0 ~ 50 ℃ Resolution: 0.1 ℃ Accuracy: ± 0.1 ℃ (8)CO2 Measurement mode: mainstream or sidestream CO2 measurement range: 0 ~ 150 mmHg CO2 resolution: 0.1 mmHg: 0 ~ 69 mmHg 0.25 mmHg: 70 ~ 150 mmHg Accuracy: 0 ~ 40 mmHg: ± 2 mmHg 41 ~ 70 mmHg: ± 5 % 71 ~ 100 mmHg: ± 8 % 101 ~ 150 mmHg: ± 10 % AwRR measurement range: Sidestream: 2 ~ 120 rpm Mainstream: 2 ~ 150 rpm AwRR accuracy: ± 1 rpm Apnea alarm: yes (9)IBP Channel: 4-channel Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measurement and alarm range: -50 ~ 300 mmHg Resolution: 1 mmHg Accuracy: ± 2 % or 1 mmHg, whichever is greater (10)Power supply: 100 ~ 240 V ~ 50/60 Hz (11)Safety class: class I, defibrillation-proof type CF applied part (12)Waterproof degree: IPX2 Shipment 1. We will ship the item within 48 hours after receiving your payment, please kindly leave your detail shipping address and telephone number, both are very important for the shipment,thank you. 2.We will upload the tracking number after shipment,you can search from both ebay and paypal.You can track online. 3. If you haven't received the item after 2 weeks of your payment, please contact me immediately! Terms of Sale 1.If you have a defective item, you want to return or discount. Please contact us within 14 days from you receive the shipment.All return items must be returned with it's original packaging and accessories. Customer is responsible for shipping charges on returned items. 2.we will refund the money to you when we get the return items. Or replace item for you. We will deal with the refund in 2 business days when we get the info from you.Please read our trade Policy before buy , if you don't agree our trade policy please don't buy it. International Buyer--Please note: Import duties,Taxes are not included in the item price.These charges are buyers' responsibility We are the manufacturer of medical equipment for 17 years, the following are our main products: ECG / ECG holter EEG / EEG Holter B-ultrasound Patient Monitor Fetal doppler Fetal Monitor Spo2 Monitor Stethoscope Medical Image.... Agent in the world! We are look for partners in the world now! Do you want to become our agent in you conutry? Join US! Skype:xuebox3 contec.med.mary # hotmail dot com Only English User Manual,Please contact us if you need other language version.thank you
Price: 1699 USD
Location: qinhuangdao
End Time: 2024-02-24T08:21:28.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money Back
Brand: CONTEC
Screen Dimensions: 13.1 Inch
Technology: Digital
Model: TS13
Features: Battery Operated, Handheld
MPN: 69450401
Country/Region of Manufacture: China
Monitor Parameters: Pulse Rate, Blood Pressure - NIBP, Blood Pressure - IBP, ECG, O2 - SpO2, CO2, CO2 - EtCO2, Respiratory Rate, Temperature