Description: 1PC Brand New OMRON SHL-Q2255 Enclosed Limit Switch - US Stock Product Specification: Shape / Structure Enclosed Limit switches service life General type Operating mechanism Snap action Actuator Panel mount roller plunger Frequency 50/60 Hz Switching mechanism Self-reset mechanism Contact configuration Single-Pole, Double-Throw type Contact form SPDT Load General load Ratings (AC): Non-Inductive load Rated voltage: 125 VAC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 1.5 A (NC) 1.5 A (NO) Rated voltage: 250 VAC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 1.5 A (NC) 1.5 A (NO) Rated voltage: 480 VAC, Resistive load: 2 A (NC) 2 A (NO) Ratings (AC): Inductive load Rated voltage: 125 VAC, Inductive load: 3 A (NC) 3 A (NO), Motor load: 2.5 A (NC) 2.5 A (NO) Rated voltage: 250 VAC, Inductive load: 2 A (NC) 2 A (NO), Motor load: 1.5 A (NC) 1.5 A (NO) Ratings (DC): Non-Inductive load Rated voltage: 8 VDC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 2 A (NC) 2 A (NO) Rated voltage: 14 VDC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 2 A (NC) 2 A (NO) Rated voltage: 30 VDC, Resistive load: 5 A (NC) 5 A (NO), Lamp load: 1.5 A (NC) 1.5 A (NO) Rated voltage: 125 VDC, Resistive load: 0.4 A (NC) 0.4 A (NO), Lamp load: 0.4 A (NC) 0.4 A (NO) Rated voltage: 250 VDC, Resistive load: 0.2 A (NC) 0.2 A (NO), Lamp load: 0.2 A (NC) 0.2 A (NO) Ratings (DC): Inductive load Rated voltage: 8 VDC, Inductive load: 5 A (NC) 5 A (NO), Motor load: 2 A (NC) 2 A (NO) Rated voltage: 14 VDC, Inductive load: 5 A (NC) 5 A (NO), Motor load: 2 A (NC) 2 A (NO) Rated voltage: 30 VDC, Inductive load: 1.5 A (NC) 1.5 A (NO), Motor load: 1.5 A (NC) 1.5 A (NO) Rated voltage: 125 VDC, Inductive load: 0.05 A (NC) 0.05 A (NO), Motor load: 0.05 A (NC) 0.05 A (NO) Rated voltage: 250 VDC, Inductive load: 0.03 A (NC) 0.03 A (NO), Motor load: 0.03 A (NC) 0.03 A (NO) Explanation The above values indicate the steady-state current. Lamp load has an inrush current of 10 times the steady-state current. Inductive load has a power factor of 0.4 Min. (AC) and a time constant of 7 ms Max. (DC). Motor load has an inrush current of 6 times the steady-state current. Inrush current NC: 15 A NO: 15 A Protective circuit Classification of protection against electric shock: Class II (Double insulation) Short-circuit protective device: 10 A fuse type gI or gG (IEC269) Ambient temperature Operating: -10 to 80 CEL (with no icing or condensation) Ambient humidity Operating: 35 to 95%RH (with no icing or condensation) Characteristics Permissible operating speed 0.1 mm/s to 0.5 m/s Permissible operating frequency (Mechanically) 120 operations / 1 minute Max. Permissible operating frequency (Electrically) 30 operations / 1 minute Max. Contact resistance 15 mOhm Max. (Initial value) (Measuring method is contact resistance meter.) Insulation resistance Between each terminal of the same polarities: 100 MOhm Min. Between live-metallic part and ground: 100 MOhm Min. Between each terminal and non-live-metallic part: 100 MOhm Min. (at 500 VDC Megger) Dielectric strength Between each terminal of the same polarities: 1,000 VAC Between live-metallic part and ground: 2,000 VAC Between each terminal and non-live-metallic part: 2,000 VAC (50/60 Hz for 1 min) Durability (Mechanically) 10,000,000 operations Min. (No load) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) Durability (Electrically) 500,000 operations Min. (Resistive load 10 A at 125 VAC) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) Pollution degree 3 (EN60947-5-1) Vibration resistance (Malfunction) Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position. Shock resistance (Destruction) 1,000 m/s2 Shock resistance (Malfunction) Contact opening is 1 ms Max. at the free position and the total travel position at 300 m/s2. Degree of protection IEC60529 (JEM): IP67 NEMA250: Type1 Applicable standard (UL) Standard No.: UL508 File number: E76675 Applicable standard (CSA) Standard No.: C22.2 NO.14 File number: LR45746 Applicable standard (TUV) Standard No.: EN60947-5-1 File number: J50062486 Applicable standard (CCC(CQC)) Standard No.: GB14048.5 File number: 2003010305072162 Applicable standard (EC Directive (Low Voltage Directive) ) 2006/95/EC Mounting specification Panel mounting, Side mounting Operating characteristics Operating Force (OF) Standard value 9.81 N Max. Release Force (RF) Standard value 1.96 N Min. Pre-Travel (PT) Standard value 1.5 mm Max. Over-Travel (OT) Standard value 2 mm Min. Movement Differential (MD) Standard value 0.5 mm Max. Operating Position (OP) Standard value 43 +/- 0.8 mm Package Include: 1 x NEW OMRON SHL-Q2255 Panel Mount Roller Plunger For Standard Load6 months warranty 60 days money back Life-time support.
Price: 14.96 USD
Location: NJ
End Time: 2024-12-04T01:05:10.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: Omron
MPN: SHL-Q2255