Description: Description:[12'' ICU Portable Medical Patient Monitor Vital Signs SpO2/PR/NIBP/ECG/RESP/TEMP]Portable Multi-parameter Patient Monitor is adaptable to adult, pediatric and neonatal usage. It can monitor vital signals as ECG, Respiratory Rate, SpO2, NIBP, TEMP and IBP.It integrates parameter measuring modules, display and recorder in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient.Features:12" high resolution color TFT LCD display.6 Standard parameters:ECG, RESP, NIBP, SPO2, TEMP, PR.Can be arbitrarily set the alarm limit, automatic sound and light alarm.The back of the machine is designed with a storage box, which can put some accessories,convenient for doctors use.Drug solubility calculation function, Arrhythmia analysis function.Built-in lithium battery,AC and DC,can provide long-term monitoring after power failure.Widely used in the Department of internal medicine, Dental practices (both pediatric and adult), oral surgery centers surgery, operation room,obstetrics and Gynecology, pediatrics, emergency center,ICU,CCU. Specification:ECGLead Mode:5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)Lead selection:I, II, III, avR, avL, avF, V,Waveform:2 chLead mode:3 Leads ( R, L, F or RA, LA, LL)Lead selection:I, II, III,Waveform:1 chGain:′2.5mm/mV, ′5.0mm/mV, ′10mm/mV, ′20mm/mV, autoHR and Alarm Range: Adult:15 ~ 300 bpmNeo/Ped:15 ~ 350 bpmAccuracy:± 1% or ± 1bpm,which greatResolution:1 bpmSensitivity:> 200 (uV P-P)Differential Input Impedance:> 5 MΩRESPARATION:Method:Impedance between R-F(RA-LL)Differential Input Impedance:>2.5 MΩMeasuring Impedance Range:0.3~5.0ΩBase line Impedance Range:0 – 2.5 KΩBandwidth:0.3 ~ 2.5 HzResp. RateMeasuring and Alarm Range Adult:0 ~ 120 rpmNeo/Ped:0 ~ 150 rpmResolution:1 rpmAccuracy:±2 rpmApean Alarm:10 ~ 40 SNIBPMethod:OscillometricMode:Manual, Auto, STATMeasuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)Measuring Period in STAT Mode:5 MinPulse Rate Range:40 ~ 240 bpmAlarm Type:SYS, DIA, MEANMeasuring and alarm range: Adult ModeSYS :40 ~ 270 mmHgDIA :10 ~ 215 mmHgMEAN:20 ~ 235 mmHgPediatric ModeSYS:40 ~ 200 mmHgDIA:10 ~ 150 mmHgMEAN:20 ~ 165 mmHgNeonatal ModeSYS:40 ~ 135 mmHgDIA:10 ~ 100 mmHgMEAN:20 ~ 110 mmHgOverpressure ProtectionAdult Mode:297±3 mmHgPediatric Mode:240±3 mmHgNeonatal Mode:147±3 mmHgSpO2Measuring Range:0 ~ 100 %Alarm Range:0 ~ 100 %Resolution:1 %Accuracy: 70% ~ 100% ±2 %0% ~ 69% unspecifiedActualization interval:about 1 Sec.Alarm Delay:10 Sec.Pulse RateMeasuring and Alarm Range:0~254bpmResolution:1bpmAccuracy:±2bpmI.5TEMP measurement:Channel:1Measuring and Alarm Range:0 ~ 50 °CResolution:0.1°CAccuracy:±0.1°CActualization interval:about 1 Sec.Average Time Constant:< 10 Sec.Package List:1×Patient Monitor1×EKG Lead wire1×NIBP Cuff1×NIBP Extension Cable1×SpO2 Sensor1×Temp Sensor1×Ground Cable5×Electrode2×Fuse1×User Manual(CD) Gift:1 x Fetal heart rate monitor1 x English user's manual FDA Disclaimer:The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:ARTG NO: 278908 ARTG Number: 278908 Statement: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item. (The seller name: Helen Zhang,City:Beijing State: Beijing Country: China Telephone number: 86-18730611603) This item has been cleaned and treated according to the manufacturer's instructions.
Price: 519 USD
Location: Monroe Township, New Jersey
End Time: 2024-12-01T02:58:31.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Usage: Department of internal medicine
Feature 3: Can be arbitrarily set the alarm limit
Feature 2: Real-time S-T segment analysis
MPN: Does Not Apply
Feature 5: with a storage box
Feature 4: automatic sound and light alarm
function 2: Arrhythmia analysis function
Feature 6: Built-in lithium battery
Intended Use/Discipline: Medical Laboratory
Brand: Carejoy
Standard configuration: SpO2, PR, NIBP, ECG, RESP, TEMP
Screen Dimensions: 12 Inch
Various interfaces: standard , trend , oxyCRG , NIBP list , big front screen
Technology: Digital
Battery: rechargeable lithium battery
Function 1: Drug solubility calculation function
Features: Battery Operated